Showing results: 61 - 75 of 142 items found.
-
Shanghai Launch Electric Co., Ltd.
The system features Microsoft Windows -based testing software, such as Windows 98m, Windows 2000 and Windows XP.Basic functions of the software the software can operate and control transformation ratio tester, transformer winding DC resistance tester, transformer feature tester. finished test can be traced through serial number, capacity or test date.
-
Vasavi Electronics
Coil Turns Tester , Turns Tester , Turns Counter , Coil Turns Counter , Toroidal Turns Tester , Bobbin Turns Tester , Coil Turns Tester , Ratio Turns Tester / Counter for Toroidal Coils, Current Transformer
-
Labodam
Automatic lubricating oils oxidation stability tester, transformer oil oxidation stability tester, distillate fuel oil oxidation stability tester, gasoline oxidation stability tester (induction period method)
-
-
SFK061 -
Shanghai Launch Electric Co., Ltd.
It is for testing the tgδ and Cx of materials and equipment such as various types of insulating material, insulating bushing, power cable and capacitor, instrument transformer and transformer. The tester is equipped with AC HV and precision standard capacitor and is easy to operate, of fully automatic testing, stable and reliable data and printable. The tester is also equipped with HV safety protector.
-
YD-Series -
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
YD series HIPOT tester is applied to test the insulation ability of electric power equipments and insulation materials at power frequency high voltage. The insulation test result of the tester is go or not go. Also the YD series HIPOT tester is a universal power source in HV test. The maximum output voltage and capacity could be customized according the requirements of custom.The tester is consists of single HV transformer and main control box. There are two kinds of HV transformer according to the insulation materials of the HV transformer.They are dry HV transformer and oil HV transformer. For the dry HV transformer the insulation material is epoxy resin.For oil HV transformer the insulation material is insulation oil. The dry HV transformer has a smaller size and less weight than oil HV transformer. But the maximum output voltage is less than 100kv for dry HV transformer. The functions of the main control box are voltage output regulation, protection in emergency and voltage/current value indication
-
SS107A -
Sanshine Electronis Co., Ltd.
The magnetic torrid ring core winding coil turns tester (SS107A) adopts the high speed center microprocessing unit circuits and precise measurement A/D circuits. This coil turns tester is used to count the coil turns of various torrid core winding coils. Like as: torrid core inductors, torrid core transformers, torrid core sensors, wate meter sensors, torrid current transformers, torrid core choke coils, etc. The tone tester is named magnetic ring core coil turn tester also.
-
Vanguard Instruments Company, Inc.
The ATRT-01 S3 is Vanguard’s fourth generation, micro-processor based, single phase, automatic transformer turns-ratio tester. The ATRT-01 S3 uses the IEEE C57.12.90 measuring method to determine the transformer turns-ratio. The transformer turns-ratio is determined by precisely measuring the voltages across the unloaded transformer windings. The ATRT-01 S3’s measuring circuitry self adjusts before each measurement to ensure turns-ratio accuracy. Two selectable test voltages, 4Vac and 40Vac, offer flexibility in testing different types of transformers.
-
CTVT-45 -
Vacuum Interrupters, Inc.
Introducing the CTVT-45 instrument transformer test set, a multi-function tester designed to test all types of current transformers and voltage transformers. It is a light-weight, rugged, user-friendly test set that performs basic and routine testing of CTs and VTs / PTs.
-
-
AJIT Electronics Co.
Theses tester sets are used for determining the di-electric BDV of insulating oils, both new and in-service from transformers, switchgear and other electrical equipments.
-
Greenlee Tools
*Quick and easy check for opens or shorts on transformers or capacitors before energizing*Provides clear indications of open circuits, short connections and confirmation that the test results are OK*Tests overhead, pad-mount and other distribution transformers as well as capacitors and capacitor banks*Tests the primary and secondary sides of de-energized transformers and capacitors without disconnecting*Helps prevent line workers from installing a fuse on a shorted transformer or capacitor*Automatic self-test featureMagnet holds the tester in place while testing
-
TE30 Lite -
Calmet Smart Calibration Devices
Electricity meters tester class 0.02%. Three phase tester of current transformers and analyser of power network quality. It makes possible electricity meters testing on the site or in the laboratory.
-
GDZRC-5A -
HV Hipot Electric Co.,Ltd.
GDZRC series DC resistance tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors. It uses new power technology,with the features of fast measurement,small size and high accuracy of measurement,which is ideal equipment of measuring transformer winding and DC resistance of big power inductance equipment.
-
MTC 2 -
Whitelegg Machines Ltd
Advanced automatic high precision electrical winding testers for testing products like alternators, stators, transformers, armatures and motors. Available as static or portable units from 6-50 kV.